ViewDCM

DICOM provenance and completeness

Original, Reconstructed and Converted DICOM

The source label in your download tells you what the platform supplied and how the DICOM file was saved. One study can contain several sources. Open the series details to see which CT images have verified Hounsfield units (HU).

Medical Image Download · Updated

The three DICOM source labels

What the platform supplied for each download label
Download labelPlatform inputHow the file was saved
Original DICOMA DICOM file or an existing DICOM dataset.A complete file is saved byte for byte. An existing dataset can be saved with a standard file header. Source details identify the method and any separate compatibility copy.
Reconstructed DICOMA source pixel matrix or compressed source frames, with imaging parameters.A new DICOM file is built from those pixels and parameters. Series details show which fields are available.
Converted DICOMA grayscale or color image rendered for the web viewer.The DICOM file stores the displayed shades or colors. Information already lost during rendering cannot be recovered from this image.

A standalone JPG, PNG or screenshot remains an ordinary image. The Converted DICOM label applies when a rendered image has been written to a DICOM file.

Reading mixed sources and HU coverage

The download lists image counts by source. For example, HU on 120/122 images means that 120 of the 122 images have verified HU. Open the series details to see the coverage and whether calibration came with the DICOM file, was supplied by the platform, or belongs to a separately identified multi-window estimate. For multi-frame files, also check the frame counts.

On DX images, 16-bit grayscale describes pixel depth. Where evidence is missing, the details indicate an unconfirmed source or missing historical detail. See the support directory for verified hospital entries.

Retrieval provenance versus viewer exports

A hospital retrieval result describes the source of the acquired images. PNG, image PDF, NRRD labels, DICOM SEG and STL exported later by a viewer are derived outputs. Viewing a study in 3D does not change the provenance of its downloaded files; STL is not original DICOM.

See the MPR and 3D walkthrough or label, SEG and STL export scope. Keep source images and provenance information so derived results can be checked against the source series.

See when CT values can be reconstructed and how the estimates compare with hospital readings.

Completeness checks

A DICOM instance may contain multiple frames. File counts need not equal the viewer's image count, and equal counts alone do not establish completeness.

What a SHA256 checksum proves

SHA256 helps check whether a file changed during transfer or storage. Matching digests can help detect corruption or modification.

A digest alone does not prove that every series was provided, or that the file came directly from a scanner. Use provenance, object reconciliation and file validation together.

When a doctor requests original imaging

  1. Check the file provenance, examination date and series in the task result. To see whether files open, select a local ZIP, folder or .dcm file in our free online DICOM viewer or a compatible desktop viewer. A preview, bit depth or HU value alone cannot prove original provenance.
  2. Keep the complete study folder and available report. Ask the receiving hospital whether it accepts USB drives, discs or a designated upload portal and which file formats it requires.
  3. If the receiving hospital requires the original file, check the details for byte-for-byte preservation. For a saved dataset, reconstructed file or converted file, ask the imaging hospital how to obtain the source file.

Technical checks do not certify clinical suitability; the receiving clinician decides whether the material meets the current need.

Frequently asked questions

Is every .dcm file original DICOM?

All three types can use the .dcm extension. Check the download label and its source details.

Can renaming JPG to .dcm restore original imaging?

No. Changing an extension does not create a complete DICOM dataset or restore missing pixels, series or acquisition parameters.

Does HU on a CT image mean it is Original DICOM?

HU describes a verified CT value scale. Reconstructed DICOM can retain HU from platform pixels and calibration. Check the file source and HU coverage separately in the download.

Does a different file count prove that images are missing?

No. A DICOM instance can contain multiple frames. Reconcile the platform's study, series, instance and frame definitions instead of comparing file totals alone.

Check my authorized imaging link →