ViewDCM

Local DICOM viewing and reconstruction

CT and MRI MPR and 3D Reconstruction: A ViewDCM Guide

Open a complete local CT or MRI DICOM folder or ZIP in ViewDCM, select a tomographic series that meets its geometry and pixel requirements, then enter MPR or 3D display. Images are parsed in your browser without being uploaded to this service. A single projection X-ray, scout image or screenshot cannot recover true internal cross-sections.

Medical Image Download · Updated

Prepare the right files

Use a complete tomographic series, rather than a report PDF, QR code or photograph of film. Keep the original archive and folder structure. If you only have a hospital link, first retrieve files through Medical Image Download and check their provenance statement.

A computer is preferable for large studies. Successful 2D viewing does not establish 3D eligibility: orientation, slice positions, pixel encoding and device resources must meet the viewer requirements.

Open a series and enter MPR

  1. Open ViewDCM and use the file/ZIP or folder button to load the complete study.
  2. Select the intended CT or MR tomographic series. Browse its 2D slices first and check the examination, body part and orientation.
  3. Select MPR. When the volume is ready, use the axial, coronal and sagittal views and follow the displayed controls for locating a point and adjusting windowing.
  4. Check the source again when switching series. If a complete cross-sectional series is required, return to 2D, select another suitable series and keep the exact error text for troubleshooting.

Choose a 3D mode

3D modes and their inputs
ModeWhat it displaysRequirement
Volume renderingImage intensities and opacity.A supported volume; no organ labels are required first.
Surface renderingA surface generated from structure labels.Extract, annotate or import labels aligned with the current images.
OverlayImages and structures together.Verify alignment before adjusting the display.

Choose the mode in the 3D workspace display controls. Lower quality or use a computer with more resources if needed. Display interpolation does not recover missing source slices. For a model file, continue to DICOM to STL.

Troubleshoot the displayed message

For support, start with non-sensitive error text, browser and device details. Do not post real DICOM files, patient information or hospital links in public comments.

Frequently asked questions

Why is MPR unavailable when my CT opens in 2D?

2D display and volume reconstruction have different requirements. Check the selected tomographic series, geometry, encoding and device resources. Do not combine scouts or different series to fill missing slices.

Does 3D reconstruction upload my images?

ViewDCM parses local images in your browser without uploading them to this service. The website still makes account and usage-statistics requests. Hospital-link retrieval is a separate server-side workflow.

Does 3D display automatically identify organs?

No. Volume rendering displays image intensities; organ surfaces require reviewed structure labels. Threshold extraction is not automatic organ recognition, and the local-model workflow requires separately prepared tools and models.

Open local DICOM in ViewDCM →