From a hospital CT link to DICOM files with measurable HU
A hospital may offer online access to a CT study without a download of the original DICOM files. For eligible CT series, ViewDCM can reconstruct DICOM files with estimated Hounsfield units (HU). Open them in a compatible CT viewer to take a point measurement or adjust the window.
Where do the CT values in a slice come from?
A CT value describes how strongly tissue attenuates X-rays relative to water. When an online study retains enough information, ViewDCM estimates CT values slice by slice and writes each value at its original pixel location. A location without a reliable estimate is left unmeasured.
Each slice includes a slope and an intercept that a DICOM viewer uses to convert stored pixel values to HU. Adjusting the window changes the brightness on screen. The reading at a given pixel stays the same.
How do I measure a point or view another plane?
Open the files in ViewDCM, choose Measure → Point HU and click the location you want to measure. Where a reading is available, the viewer displays its value and labels it HU (estimated).
The files also retain slice position, orientation and pixel spacing. If the slices are continuous and the geometry is complete, multiplanar reconstruction (MPR) lets you view the same scan in the coronal or sagittal plane.
Which online CT studies qualify?
One examination may include cross-sectional CT images, scouts and 3D previews. ViewDCM checks each series available through the hospital link or QR code to see which slices support HU reconstruction.
If the hospital supplies original DICOM files with measurable HU, use those directly. A single JPG or a screenshot of a report contains too little information to determine the CT value at each location.
How close are the estimates to the hospital readings?
We sampled 86 slices from eight CT series in one examination at one hospital. For each point we selected the same slice and pixel in the hospital viewer and the reconstructed DICOM. We compared both the 8-bit and the 16-bit files with the hospital readings at the same 1,422 locations.
| Difference | 8-bit effective | 16-bit |
|---|---|---|
| Mean absolute difference (HU) | 7.51 | 5.53 |
| Within 20 HU | 1,356/1,422 (95.4%) | 1,379/1,422 (97.0%) |
| Largest difference (HU) | 36.81 | 32.20 |
In this sample, 43 points in the 16-bit files differed from the hospital by more than 20 HU. Other studies need their own checks. If a clinical decision depends on a precise CT value, ask the clinician to verify it on the original scan.
Does the reading change in a different viewer?
We opened both sets of files in another DICOM viewer and measured the same 1,422 pixels again. Every reading was within 0.001 HU of the calibrated value stored in the corresponding file.
Additional error measurements and sampling details
| Difference | 8-bit effective | 16-bit |
|---|---|---|
| Mean signed error (HU) | +0.12 | −0.05 |
| 95th percentile of absolute error (HU) | 19.54 | 16.90 |
| Within 10 HU | 1,040/1,422 (73.1%) | 1,189/1,422 (83.6%) |
| More than 20 HU apart | 66/1,422 (4.6%) | 43/1,422 (3.0%) |
Signed error is the estimate minus the hospital reading. A positive value means the estimate was higher. The 95th percentile is the absolute difference that about 95% of the sampled points fell at or below.
Only locations with readings in both files and in the hospital viewer were counted. The sample included 216 points selected separately for a further check. At these points the 8-bit mean absolute error was 6.23 HU, with 211/216 readings within 20 HU of the hospital value. The 16-bit figures were 4.43 HU and 212/216.
Frequently asked questions
I have both files. Which one should I open?
Both versions support point measurements in estimated HU. Use the 16-bit file when you need to distinguish small differences in CT values.
A dark area says “No valid pixels”. What should I record?
Leave the value blank. Zero HU is a specific reading. Entering zero would count a missing value as a measurement.